Tennessee tri-star emblem

ERRORS - West TN Linked Digital Communications System

Dashboard for Digital Repeaters
DashboardLast HeardDIAGNOSTICSRepeatersHotspotsBridgesAdd Your RepeaterUsageRepeater MapRoutingHA Status
Hidden troubleshooting page — public but intentionally unlinked.
This page contains only redacted timing/state metadata. It does not display passwords, tokens, passphrases, IPSC authentication keys, Authorization headers, literal IP addresses, or raw DMR voice payloads.

Copy/paste diagnostic report

After reproducing a problem, press Refresh Now, then Copy Report and paste the entire box back into ChatGPT. The diagnostic code is a quick classification, while the evidence lines let us confirm or reject that classification.

Current interpretation

Diagnostic code
-
ACTIVE worker
-
Generated
-
Loading...

What these tests reveal

TestWhat it observesExample evidenceWhat that would prove / disprove
A. Hotspot/HBlink stream durationRecent EXTERNAL-ACCESS stream start/end events copied from the ACTIVE worker to WTN01.stream_end duration=3.8If HBLink itself records a ~3–4 second end while the hotspot PTT remains held, the failure is upstream/on the worker side. It is not the 119-second limit.
B. WTN01 HBP→IPSC starvationFiltered ipsc2hbpc journal signatures on WTN01.stream timeout ... 34 consecutive silence bursts ... VOICE_TERMShows WTN01 received more than ~2.04 seconds of continuous missing HBP voice and intentionally terminated the Motorola-side call. Shorter inter-node jitter is concealed and must not unkey the repeater. This points between the ACTIVE worker and translator.
C. Long source callWhether ACTIVE-worker telemetry continues for at least 10 seconds.OK-SOURCE-LONGDisproves a 3–4 second source/HBlink timeout. If the repeater still drops, focus on WTN01 translator/IPSC/repeater handling.
D. Service stabilityDirector, dashboard, Nginx and every ipsc2hbpc instance state/restart count.state=failed or increasing restartsShows a service restart/crash could be ending calls independently of hotspot PTT.
E. 119-second bridge policyCompleted stream durations reported by the bridge.duration≈119Confirms the intended hard bridge limit. A 3–4 second failure cannot be explained by this policy unless evidence actually reports an early bridge-generated end.
F. TGIF isolationNODEv223 runs TGIF in a separate HBLink sidecar instead of as a member of the core TS2 conference bridge.E-TGIF-SIDECAR-RETURNShows TGIF return traffic was caught inside the isolated edge. The main hotspot↔repeater call state is not modified by the TGIF process.
G. Hotspot HBP session/end reasonRecent EXTERNAL-ACCESS events and retained historical signatures identify real terminators, session closes, source timeouts, and stream replacements.E-HOTSPOT-VOICE-TERMINATOR, E-HOTSPOT-DMRD-STOPPED, or E-HBP-STREAM-RESTARTShows whether the main core itself is losing/replacing the hotspot stream after the TGIF topology rollback.
H. Core regression topologyThe worker release contract requires the core TS2 conference bridge to contain only INTERNAL-REPEATERS and EXTERNAL-ACCESS. TGIF must be absent.NODEv223 core=v212 topologyProves the first NODEv213 topology delta has been removed rather than masked by another packet-flow compatibility patch.

Recent bridge events

Time CTEventSystemRadioRepeaterTSTGStreamDuration

WTN01 translator signatures

Only troubleshooting-relevant journal lines are shown and redacted.

Loading...

Service state

ServiceStateRestarts